String Inverter Three Phase – 2MPPT

5 ★★★★★

SKU: PCCC2006014

Liên hệ:

Mô tả sản phẩm:

Model SUN-18K-G05 SUN-20K-G05 SUN-22K-G05 SUN-23K-G05 SUN-25K-G05
PV String Input Date
Max. PV Input Power(kW) 23.4 26 28.6 29.9 32.5
Max. PV Input Voltage(V) 1100
Start-up Voltage(V) 250
MPPT voltage range(V) 200-1000
Rated PV Input voltage(V) 600
Max. Input Short Circuit Current (A) 39+39
Max. Operating PV Input Current(A) 26+26
No. of MPP Trackers/No. of Strings per MPP Tracker 2/2+2
AC Output Side
Rated AC Output Active Power(kW) 18 20 22 23 25
Max. AC Output Apparent Power(kVA) 19.8 22 24.2 25.3 27.5
Rated AC output current (A) 27.3/26.1 30.3/29 33.4/31.9 34.9/33.4 37.9/36.2
Max. AC Output Current(A) 30/28.7 33.3/31.9 36.7/35.1 38.4/36.7 41.7/39.8
Rated output voltage/range (V) 220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form 3L/N/PE
Rated Output Grid Frequency/range(Hz) 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3%
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 98.50%
Euro Efficiency 98%
MPPT Efficiency >99%
Equipment Protection
DC Reverse Polarity Protection Yes
AC Output Overcurrent Protection Yes
AC Output Overvoltage Protection Yes
AC Output Short Circuit Protection Yes
Thermal Protection Yes
Insulation Impedance Detection Yes
DC Component Monitoring Yes
Arc Fault Circuit Interrupter (AFCI) Optional
Anti-islanding Protection Yes
Residual Current Detection Yes
Surge Protection Level TYPE II(DC),TYPE II(AC)
DC Switch Yes
Interface
Communication Interface RS485/RS232
Monitor Mode GPRS/WIFI/Bluetooth/4G/LAN(optional)
General Data
Operating Temperature Range (°C) -25 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0~100%
Permissible Altitude (m) 4000m
Noise (dB) ≤ 50dB(A)
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC),OVC III(AC)
Cabinet Size (WxHxD mm) 362mm*527mm*220mm(Excluding connectors and brackets)
Weight [kg] 20
Warranty [year] 5 years
Type Of Cooling Intelligent air cooling
Grid Regulation IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2